All Systems Operational

Connectivity




Operational

Power




Operational

Environment




Operational

Other Systems and Services




Operational

Cloud Services




Operational

Infrastructure as a Service




Operational

External Services

MS Office365

Scheduled Maintenance

Schedule

April 28, 2025 07:00 - 16:00 CEST

Components

Power

Locations

MTH-R1, MTH-R2, MTH-R3

Description

BMIT Technologies will be performing off-load generator maintenance on Generator 5 at Handaq [MTH] as per the below schedule. Schedule: Start: 28/04/2025 - 07:00 CEST End: 28/04/2025 - 16:00 CEST We are not expecting these works to be service-affecting. However, during this period infrastructure will be running with reduced resilience. We perform maintenance to continue to deliver optimal performance, reliability, and, security. We strive to perform them without impact on our customers. However, the possibility always exists that a maintenance event can have unintended consequences up to and including unplanned or extended service interruption. We hope you understand that such maintenance is necessary to benefit you and your customers.

Schedule

May 5, 2025 06:00 - 09:00 CEST

Components

Power

Locations

MTH-R1, MTH-R2, MTH-R3

Description

BMIT Technologies plc shall be performing MTH On-load generator testing as per the below schedule. Schedule: Start: 05/05/2025 - 06:00 CEST End: 05/05/2025 - 09:00 CEST BMIT Technologies plc shall be closely monitoring progress during this maintenance and will keep you informed of development or prior to taking any required action. BMIT Technologies plc performs maintenance to continue delivering optimal performance, reliability, and security. We strive to perform them without impact on our customers. However, the possibility always exists that a maintenance event can have unintended consequences up to and including unplanned or extended service interruption. We hope you understand that such maintenance is necessary to benefit you and your customers.

Schedule

May 5, 2025 07:00 - May 6, 2025 16:00 CEST

Components

Environment

Locations

MTS-R1

Description

BMIT Technologies plc shall be performing scheduled maintenance on the cooling units within MTS-R1 as per the below. Schedule: Day 1: Start: 05/05/2025 - 07:00 CEST End: 05/05/2025 - 16:00 CEST Day 2: Start: 06/05/2025 - 07:00 CEST End: 06/05/2025 - 16:00 CEST Works will proceed on a unit-by-unit basis. We are not expecting these works to be service-affecting. However, during this period, brief temperature fluctuations might be experienced. BMIT Technologies plc shall be closely monitoring progress during this maintenance and will keep you informed of development or prior to taking any required action. BMIT Technologies plc performs maintenance to continue to deliver optimal performance, reliability, and security. We strive to perform them without impact on our customers. However, the possibility always exists that a maintenance event can have unintended consequences up to and including unplanned or extended service interruption. We hope you understand that such maintenance is necessary to benefit you and your customers.

Schedule

May 5, 2025 07:00 - May 8, 2025 20:00 CEST

Components

Power

Locations

MTH-R3

Description

BMIT Technologies shall perform scheduled maintenance on the UPS units of MTH-R3 as per the schedule below. Schedule: Day 1 Start: 05/05/2025 - 07:00 CEST End: 05/05/2025 - 20:00 CEST Day 2 Start: 06/05/2025 - 07:00 CEST End: 06/05/2025 - 20:00 CEST Day 3 Start: 07/05/2025 - 07:00 CEST End: 07/05/2025 - 20:00 CEST Day 4 Start: 08/05/2025 - 07:00 CEST End: 08/05/2025 - 20:00 CEST BMIT Technologies plc shall be closely monitoring progress during this maintenance and will keep you informed of development or prior to taking any required action. BMIT Technologies plc performs maintenance to continue to deliver optimal performance, reliability, and security. We strive to perform them without impact on our customers. However, the possibility always exists that a maintenance event can have unintended consequences up to and including unplanned or extended service interruption. We hope you understand that such maintenance is necessary to benefit you and your customers.

Schedule

May 5, 2025 07:00 - May 8, 2025 20:00 CEST

Components

Power

Locations

MTS-R1

Description

BMIT Technologies shall perform scheduled maintenance on the UPS units of MTS-R1 as per the schedule below. Schedule: Day 1 Start: 05/05/2025 - 07:00 CEST End: 05/05/2025 - 20:00 CEST Day 2 Start: 06/05/2025 - 07:00 CEST End: 06/05/2025 - 20:00 CEST Day 3 Start: 07/05/2025 - 07:00 CEST End: 07/05/2025 - 20:00 CEST Day 4 Start: 08/05/2025 - 07:00 CEST End: 08/05/2025 - 20:00 CEST BMIT Technologies plc shall be closely monitoring progress during this maintenance and will keep you informed of development or prior to taking any required action. BMIT Technologies plc performs maintenance to continue to deliver optimal performance, reliability, and security. We strive to perform them without impact on our customers. However, the possibility always exists that a maintenance event can have unintended consequences up to and including unplanned or extended service interruption. We hope you understand that such maintenance is necessary to benefit you and your customers.

Schedule

May 5, 2025 08:00 - 12:00 CEST

Components

Power

Locations

MTS-R1

Description

BMIT Technologies plc shall be performing MTS On-load generator testing as per the below schedule. Schedule: Start: 05/05/2025 - 08:00 CEST End: 05/05/2025 - 12:00 CEST BMIT Technologies plc shall closely monitor progress during this maintenance and will keep you informed of development or prior to taking any required action. BMIT Technologies plc performs maintenance to continue delivering optimal performance, reliability, and security. We strive to perform them without impact on our customers. However, the possibility always exists that a maintenance event can have unintended consequences up to and including unplanned or extended service interruption. We hope you understand that such maintenance is necessary to benefit you and your customers.

Schedule

May 7, 2025 08:30 - 16:30 CEST

Components

Cloud Services

Locations

Cloud Control Panel

Description

BMIT Technologies plc shall be performing scheduled maintenance on its Cloud Control Panel as per the below schedule. Schedule: Start: 07/05/2025 - 08:30 CEST End: 07/05/2025 - 16:30 CEST BMIT Technologies plc is not expecting these works to be service-affecting. However, during this maintenance window, the control panel may experience intermittent periods of unavailability. Customers using the control panel may also experience delays in billing, provisioning, and management of subscriptions. BMIT Technologies plc performs maintenance to continue delivering optimal performance, reliability, and security. We strive to perform them without impact on our customers. However, the possibility always exists that a maintenance event can have unintended consequences up to and including unplanned or extended service interruption. We hope you understand that such maintenance is necessary to benefit you and your customers.